Glossary

AJB Array Connection Box, an enclosure where cables are joined and/or connected to electrical equipment and/or protective devices.
Altitude

The angle between the sun’s rays and the horizontal plane. (see graphic)

Altitude = 90° – Latitude

Array PV Modules arranged in strings
Azimuth The angle on the horizontal plane. The angles to the east are negative, to the west positive.
By-pass diode A diode that is connected in parallel with a PV module, typically 6A, 600V Schottky Diodes.
Cable (Size, Insulation)

Minimum size: 2.5mm2

Double insulated and flex type, uv and heat resistance. Insulation voltage: 1.2 x Uoc_array

Cable Voltage drop Should be less than 5% between the PV array and the inverter
Class II Equipment with double insulation, or reinforced insulation.
Conversion Efficiency See Inverter Efficiency
Diffuse radiation The solar radiation received from the sun after its direction has been changed by scattering in the atmosphere [kW/m2]
Direct radiation The solar radiation received direct from the sun [kW/m2]
Earthing

Reasons for earthing:

  1. Equipotential bonding to avoid uneven potentials across and installation
    (min 6mm2 earthing conductor)
  2. Protective earthing to provide a path for fault currents to flow
  3. Lighting protection
Energy Power * time [Wh}

1Ws = 1 Joule

1Wh = 3’600 Joule = 3.6kJ

1kWh = 3’600’000 Joule = 3.6MJ

Energy Efficiency EE means using less electricity to accomplish the same activity.
Fill Factor The fill factor is a ratio of max power to the product of Isc and Voc and is an operating characteristic which indicates the performance of a cell: FF := (ImpVmp) / (IscVoc) = Pmp/(IscVoc). Typical FF: 0.6 .. 0.7
Global radiation Is the sum of the beam of the direct and diffuse radiations arriving on a surface. [kW/m2]
Inverter Device which invert the DC PV Power into AC Power
Inverter Efficiency

Converting the D.C. Power to A.C. Power hcon

Tracking the max power point of the PV Array

For the Solarmax (SWISSPROF Standard Inverter) it is around 97%.

Irradiation

Is the Energy per unit area of a surface by integrating the irradiance over a specific time.

It is the integral over the time or the sum for each hour given over the day/month/year etc.

Load Profile

A time based load, usually over one day period to show when is the most load on the system and when does the PV system generate the power.

O&M Operation and Maintenance
Peak Sun Hours

It is the equivalent number of hours in a day of irradiation when the solar power intensity is 1kW/m2.

PSH := H [kWh/m2] / 1kW/m2 = xxhours

Photoelectric effect

If light with sufficient energy falls onto silicon arranged to form a p-n junction and penetrates to a point near the junction, the photo-electric effect will create free electrons near the junction.

PTM Pusat Tenaga Malaysia
PV Photovoltaic
PV System Complete Photovoltaic System
SPD

Surge Protective Device

String Amount of PV Modules in series
Wp Peak Power